The counterbalanced transfer window separates the inter-chamber from the sterile work zone. Inner Transfer Window Isolates Sterile Product A locking mechanism with an airtight seal holds the waste containers in place under the work surface, and the containers can be quickly released, removed and replaced. This waste system maintains sterility and increases workspace. Protect workers from sharps and waste, which are disposed of through covered negative-pressure drop tubes. Use this CACI, which meets USP 800 standards, to adequately protect personnel and the environment outside the pharmacy when handling hazardous drugs. This minimizes the possibility of hazardous materials migrating from the workspace into the surrounding room, and of contamination migrating into the work zone. The HEPA-filtered interchange compartment maintains a negative pressure relative to the work area, which operates at a negative air pressure relative to the surrounding room. Provide a certified ISO Class 5 sterile environment with this compounding aseptic containment isolator (CACI), which meets or exceeds the requirements of USP 797 for moving product in and out and for containing particulates and volatile gases. ![]() The cool white lighting and open sight lines help workers see the work area more clearly. Provide maximum knee and thigh clearance and proper height for optimal leg and upper-body support with the adjustable base. Optional Adjustable Base Encourages Comfortable Work Posture The oval slanted glove ports and the six-hook, three-position IV bar improve your reach while ensuring proper compounding distance and height. This provides each worker with a customized work space for increased comfort and reduced arm, neck and shoulder strain. The large work zone lets workers place the interchange on the left or right sides of the 4-foot units, or on the left, right, or both sides at once of the 6-foot units. ![]() It creates a negative-pressure ISO Class 5 clean-air environment to prevent contamination and protect personnel when compounding hazardous sterile preparations.Įrgonomics Expanded Work Zone Supports Flexible Workflow ![]() Meet USP 797 and USP 800 requirements when compounding hazardous drugs with this PharmaGard total exhaust compounding aseptic containment isolator. The PharmaGard ES NTE800 Total Exhaust Compounding Containment Pharmacy Isolator creates negative pressure ISO Class 5 clean air environment for aseptic compounding of hazardous drugs and chemotherapy drugs to meet USP 797 and 800 requirements.
0 Comments
Leave a Reply. |